Skip to main content

Search

Search components and kits across the catalog

EVE Energy INR21700-40PL

Extreme high-drain tabless 21700 cell from EVE Energy. 4000mAh capacity with a massive 70A continuous discharge rating enabled by its tabless electrode design. The value king for extreme power builds at ~$2.35/cell. Successor to the EVE 40P with significantly improved current capability.

In brief: 21700 Li-ion battery cell. 4000mAh capacity. 34A continuous discharge.

Specs verified Oct 16, 2026

Price History

Price History
Price changes tracked by the crawler

Current best price $4.99. Over the past 90 days: low $2.35, high $5.99, average $5.06 — down 1% vs average.

  • 18650 Battery
  • 18650 Battery Store
  • IMR Batteries
  • Li-ion Wholesale
Jul 21Jul 29Aug 6Aug 14Aug 22Aug 30Sep 7Sep 15Sep 23Oct 1Oct 9$2.00$3.00$4.00$5.00$6.00

Reviews

No reviews yet — be the first to share your experience.

Sign in with Google to leave a review.

Specifications

Cell Specs

Form Factor
21700
Chemistry
Li-ion
Capacity
4000mAh
Continuous Discharge
34.00A

Physical

Weight
65 g
Dimensions (L×W×H)
70mm × 21mm × 21mm

Resources

Official Batemo Page

Manufacturer Page<p>Get everything you need for the lithium-ion battery cell EVE Energy INR21700-40PL: Extensive measurement data in the total operation regime, a high-precision, physical battery model with global validity, and a teardown report that contains all details about materials and microstructures.</p> <table> <colgroup> <col width="50%"> <col width="50%"> </colgroup> <tbody> <tr> <td>Cell Origin</td> <td style="text-align:right">purchased on free market</td> </tr> <tr> <td>Cell Format</td> <td style="text-align:right">21700</td> </tr> <tr> <td>Dimen­sions</td> <td style="text-align:right">21.1 x 70.1&nbsp;mm</td> </tr> <tr> <td>Weight</td> <td style="text-align:right">65.2 g</td> </tr> <tr> <td>Capacity<br> <span class="collapseomatic noarrow" id="id699f755b8d751" tabindex="0" alt="definition" title="definition">defin­i­tion</span><span id="swap-id699f755b8d751" alt="'close'" class="colomat-swap" style="display:none;">close</span><div id="target-id699f755b8d751" class="collapseomatic_content collapsible_orange"> The nominal capacity origi­nates from the manufac­tur­er’s data sheet, if avail­able. When the data sheet is unavail­able, the nominal capacity is estimated. Batemo measured the C/10 capacity by discharging the cell at an ambient temper­a­ture of 25°C from 100% with a constant current of 0.40A (0.1C) until reaching the voltage of 2.5V. The thermal boundary condi­tion is free convection.<br> </div></td> <td style="text-align:right"> <span style="font-size: 10px">nominal</span>&nbsp;4.00 Ah<br> <span style="font-size: 10px">C/10</span>&nbsp;4.13 Ah</td> </tr> <tr> <td>Current<br> <span class="collapseomatic noarrow" id="id699f755b8d7db" tabindex="0" alt="definition" title="definition">defin­i­tion</span><span id="swap-id699f755b8d7db" alt="'close'" class="colomat-swap" style="display:none;">close</span><div id="target-id699f755b8d7db" class="collapseomatic_content collapsible_orange"> All quanti­ties are measure­ment results from the Batemo battery labora­tory.<br> The contin­uous current is the highest current that completely discharges the cell without overheating it. There­fore, the cell is discharged from 100% state of charge (SOC) at an ambient temper­a­ture of 25°C with a constant current until a residual state of charge of 10% and either the lower voltage limit of 2.5V or 90% of the maximum surface temper­a­ture (72°C) is reached.<br> The peak current is the current that the cell can supply for 5 minutes. The cell is there­fore discharged from 100% SOC at an ambient temper­a­ture of 25°C with a constant current until it reaches either the lower voltage limit of 2.5V or the maximum surface temper­a­ture of 80°C after 5 minutes. For cells that reach the maximum surface temper­a­ture, the measured current is taken directly as the peak current. For cells that do not reach the maximum surface temper­a­ture after 5 minutes because they reach the lower voltage limit first, the measured current is multi­plied by a correc­tion factor that estimates the current that would have heated the cell to the maximum surface temper­a­ture within 5 minutes.<br> The thermal boundary condi­tion is free convec­tion. These operating conditions may be outside the cell manufacturer’s specification.<br> </div></td> <td style="text-align:right"> <span style="font-size: 10px">contin­uous</span>&nbsp;34.4 A<br> <span style="font-size: 10px">peak</span>&nbsp;44.4 A</td> </tr> <tr> <td>Energy<br> <span class="collapseomatic noarrow" id="id699f755b8d830" tabindex="0" alt="definition" title="definition">defin­i­tion</span><span id="swap-id699f755b8d830" alt="'close'" class="colomat-swap" style="display:none;">close</span><div id="target-id699f755b8d830" class="collapseomatic_content collapsible_orange"> Batemo measured the C/10 energy by discharging the cell at an ambient temper­a­ture of 25°C from 100% with a constant current of 0.40A (0.1C) until reaching the voltage of 2.5V. The thermal boundary condi­tion is free convection.<br> </div></td> <td style="text-align:right"> <span style="font-size: 10px">C/10</span>&nbsp;15.2 Wh</td> </tr> <tr> <td>Power<br> <span class="collapseomatic noarrow" id="id699f755b8d87c" tabindex="0" alt="definition" title="definition">defin­i­tion</span><span id="swap-id699f755b8d87c" alt="'close'" class="colomat-swap" style="display:none;">close</span><div id="target-id699f755b8d87c" class="collapseomatic_content collapsible_orange"> All quanti­ties are measure­ment results from the Batemo battery labora­tory.<br> The contin­uous power is the highest power that completely discharges the cell without overheating it. There­fore, the cell is discharged from 100% state of charge (SOC) at an ambient temper­a­ture of 25°C with a constant current until a residual state of charge of 10% and either the lower voltage limit of 2.5V or 90% of the maximum surface temper­a­ture ( 72°C) is reached.<br> The peak power is the power the cell can supply for 5 minutes. The cell is there­fore discharged from 100% SOC at an ambient temper­a­ture of 25°C with a constant current until it reaches either the lower voltage limit of 2.5V or the maximum surface temper­a­ture of 80°C after 5 minutes. For cells that reach the maximum temper­a­ture limit, the measured power is directly taken as peak power. For cells that do not reach the maximum surface temper­a­ture after 5 minutes because they reach the lower voltage limit first, the measured power is multi­plied by a correc­tion factor that estimates the power that would have heated the cell to the maximum surface temper­a­ture within 5 minutes.<br> The thermal boundary condi­tion is free convec­tion. These operating conditions may be outside the cell manufacturer’s specification.<br> </div></td> <td style="text-align:right"> <span style="font-size: 10px">contin­uous</span>&nbsp;118 W<br> <span style="font-size: 10px">peak</span>&nbsp;153 W</td> </tr> <tr> <td>Energy Density<br> <span class="collapseomatic noarrow" id="id699f755b8d8c6" tabindex="0" alt="definition" title="definition">defin­i­tion</span><span id="swap-id699f755b8d8c6" alt="'close'" class="colomat-swap" style="display:none;">close</span><div id="target-id699f755b8d8c6" class="collapseomatic_content collapsible_orange"> The energy densi­ties result from the C/10 energy, the cell weight and the cell volume.<br> </div></td> <td style="text-align:right"> <span style="font-size: 10px">gravi­metric</span>&nbsp;233 Wh/kg<br> <span style="font-size: 10px">volumetric</span>&nbsp;618 Wh/l</td> </tr> <tr> <td>Power Density<br> <span class="collapseomatic noarrow" id="id699f755b8d911" tabindex="0" alt="definition" title="definition">defin­i­tion</span><span id="swap-id699f755b8d911" alt="'close'" class="colomat-swap" style="display:none;">close</span><div id="target-id699f755b8d911" class="collapseomatic_content collapsible_orange"> The power densi­ties result from the peak power, the cell weight and the cell volume.<br> </div></td> <td style="text-align:right"> <span style="font-size: 10px">gravi­metric</span>&nbsp;2.35 kW/kg<br> <span style="font-size: 10px">volumetric</span>&nbsp;6.23 kW/l</td> </tr> </tbody> </table>

Frequently Asked Questions

We use cookies for analytics. Privacy Policy